The gas sampling pump is a self-priming pump that can be used with a gas detector.
The gas sampling pump is a self-priming pump that can be used with a gas detector.
The gas sampling pump is a self-priming pump that can be used on a gas detector. The principle uses a carbon membrane self-priming type. The gas to be detected can be pumped through the sampling pump, and the gas detector is used to calibrate the gas leak. The content is small, the operation is simple, and the pumping probe is extended.
Display method:LCD
Inspiratory flow:500ml/min
Working humidity:≤97%RH
Preheat time:<20S
Standard configuration:Probe, Hose, Charger
Operating Voltage:DC3.7v 1800mAH
Alarm volume:75dB
Ambient temperature:-20 ~50℃
Dimensions:225mmx65mmx30mm
Probe length:220mm
Model | Range | L-alarm | H-alarm |
CO | 0-1000ppm | 35ppm | 200ppm |
O2 | 0-30%vol | 19.5%vol | 23.5%vol |
H2 | 0-100%LEL | 20%LEL | 50%LEL |
H2S | 0-100ppm | 10ppm | 20ppm |
CH4 | 0-100%LEL | 20%LEL | 50%LEL |
C2H4O | 0-20ppm | 10ppm | 15ppm |
C2H4 | 0-100%LEL | 20%LEL | 50%LEL |
C3H8 | 0-100%LEL | 20%LEL | 50%LEL |
C2H5OH | 0-100%LEL | 20%LEL | 50%LEL |
NH3 | 0-100ppm | 25ppm | 50ppm |
CL2 | 0-20ppm | 5ppm | 10ppm |
O3 | 0-20ppm | 5ppm | 10ppm |
SO2 | 0-100ppm | 2ppm | 5ppm |
PH3 | 0-20ppm | 0.3ppm | 5ppm |
CO2 | 0-50000ppm | 1000ppm | 2000ppm |
NO | 0-250ppm | 20ppm | 50ppm |
NO2 | 0-20ppm | 5ppm | 10ppm |
HCN | 0-500ppm | 10ppm | 20ppm |
HCL | 0-50ppm | 10ppm | 20ppm |
CH2O | 0-10ppm | 2ppm | 5ppm |
VOC | 0-100ppm | 20ppm | 50ppm |
C6H6 | 0-100ppm | 20ppm | 50ppm |