Call: +91-8143812346
AI2000 M4 Multi 4 in 1 Gas Detectors

AI2000 series 4 in 1 gas detector is a kind of fast response and high accuracy multi gas measurement device. With internal sampling pump, fast sampling speed, and available for measuring 4 gases at the same time, including 4 toxic gases and CO2 gas. Special high intensity engineering plastics housing, suitable for different kinds of situation and environment.

Get Quote Now

Fast response & high accuracy

– with internal sampling pump, response time ≤30s

– using world top brand sensors, high precision, the detection result is approved by the third testing organization at once.

Multi gases measurement

– Can measure up to 5 gases at the same time, including four toxic gases and CO2 gas, the four toxic gases are available for customization, which can meet the detection requirement of different situation.

Comprehensive functions

– gas concentration unit PPM and mg/m3 can be shifted by one press.

– With Self-calibration and zero calibration functions, making the detection more accurate and reliable.

– One press to restore factory setting, free from the bother of mis-operation

Alarm mode

– Alarm with light, sound and vibration, ensuring the safety of the users.

– Alarm point is settable according to the specific requirements.

Data logging

– Storage capacity of over 100000 sets, the historical detected data can be read on the detector quickly.

Long operation time

– High capacity of lithium polymer rechargeable battery, for toxic gas: 14h continuously. For combustible gas: 10 h continuously.

High quality case

– Special high intensity engineering plastics housing, suitable for different kinds of situation and environment

– IP65 protection degreewater-proof, dust-proof, explosion-proof

Industry

Application: Confined Space, Combustible Detection, Oxygen Detection, Toxic Detection

Situation: Furniture, wallpaper, coating, papermaking, pharmacy, health care, disinfection, chemical fertilizer, livestock farm, green household,  agricultural production.

Sampling With internal sampling pump, flow rate is up to 1L/min
Precision ≤±3%F.S. (higher precision is available)
Response Time ≤10S
Zero shift ≤±1%(F.S./year)
Display LCD dot matrix display, with display of gas type, real time gas concentration, battery power, time, gas unit.
Temperature -20℃~50℃
Humidity 0-95%RH (non-condensing)
Explosion-Proof ExibⅡCT4
Degree of protection IP65
Alarm Sound: 85dBLight: LED, low alarm: blue, high alarm: red

Vibration: the detector will vibrate when powered on

Alarm point is settable according to customer requirement.

Battery 3.6V 2300mAh lithium polymer rechargeable battery, operate time is about 12h continuously, charging time: 4-6 h
Dimensions 205x75x32mm
Weight 330g
Warranty 12 months
Gas Range Other available ranges Resolution
CO 0-1000ppm 0-100ppm, 0-500ppm, 0-2000ppm, 0-5000ppm, 0-10000ppm 0.1ppm, 1ppm
H2S 0-100ppm 0-10ppm, 0-50ppm, 0-500ppm, 0-1000ppm, 0-10000ppm 0.01, 0.1, 1ppm
O2 0-30%VOL 0-5%VOL, 0-25%VOL, 0-50%VOL, 0-100%VOL 0.01%VOL
EX / CH4 0-100%LEL 0-100%VOL 1%LEL, 0.01%VOL
N2 0-100%VOL 0.01%VOL
NH3 0-100ppm 0-50ppm, 0-500ppm, 0-1000ppm, 0-5000ppm 0.01, 0.1, 1ppm
CL2 0-10ppm 0-20ppm, 0-50ppm, 0-100ppm, 0-200ppm, 0-500ppm 0.01. 0.1ppm
H2 0-1000ppm 0-100%LEL, 0-2000ppm, 0-10000ppm, 0-40000ppm, 0-4%VOL 1%LEL, 1ppm
CH2O 0-10ppm 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm 0.01, 0.1, 1ppm
O3 0-50ppm 0-1ppm, 0-10ppm, 0-20ppm, 0-100ppm, 0-500ppm, 0-1000ppm 0.01, 0.1, 1ppm
CO2 0-5000ppm 0-2000ppm, 0-10000ppm, 0-20000ppm, 0-50000ppm 1ppm
NO 0-100ppm 0-20ppm, 0-50ppm, 0-500ppm, 0-1000ppm, 0-4000ppm 0.01, 0.1, 1ppm
NO2 0-20ppm 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-4000ppm 0.01, 0.1, 1ppm
NOX 0-20ppm 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-4000ppm 0.01, 0.1, 1ppm
SO2 0-10ppm 0-20ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-2000ppm 0.01, 0.1, 1ppm
ETO 0-10ppm 0-20ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm 0.01, 0.1, 1ppm
PH3 0-10ppm 0-20ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm 0.01, 0.1, 1ppm
HCL 0-10ppm 0-20ppm, 0-50ppm, 0-100ppm 0.01ppm
HCN 0-10ppm 0-20ppm, 0-50ppm, 0-100ppm 0.01ppm
COCL2 0-1ppm 0.01ppm
CLO2 0-10ppm 0-20ppm, 0-50ppm, 0-100ppm 0.01ppm
SiH4 0-10ppm 0-50ppm 0.01ppm
F2 0-10ppm 0-1ppm 0.01ppm
HF 0-10ppm 0.01ppm
HBr 0-10ppm 0-50ppm, 0-100ppm 0.01ppm
H2O2 0-100ppm 0-500ppm, 0-1000ppm, 0-2000ppm 0.01, 0.1, 1ppm
B2H6 0-5ppm 0-10ppm 0.01ppm
AsH3 0-1ppm 0-10ppm, 0-50ppm 0.01ppm
GeH4 0-1ppm 0.01ppm
N2H4 0-1ppm 0.01ppm
THT 0-100ppm 0-50mg/m3, 0-100mg/m3 0.01ppm, 0.01mg/m3
Br2 0-5ppm 0-10ppm, 0-50ppm 0.01ppm
C2H2 0-100ppm 0-2.3%VOL 0.01ppm, 0.01%VOL
C2H4 0-10ppm 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 2.4%VOL 0.01, 0.1, 1ppm, 0.01%VOL
CH3OH 0-100ppm 0-50ppm, 0-500ppm, 0-1000ppm 0.01, 0.1, 1ppm
C2H5OH 0-100ppm 0-50ppm, 0-500ppm, 0-1000ppm 0.01, 0.1, 1ppm
CH4S 0-100ppm 0.01ppm
C8H8 0-10ppm 0-50ppm, 0-100ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm 0.01, 0.1, 1ppm
C4H6 0-10ppm 0-50ppm, 0-100ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm 0.01, 0.1, 1ppm
VOC/TVOC 0-10ppm 0-1ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm 0.001, 0.01, 0.1, 1ppm
CH3Br 0-10ppm 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm 0.001, 0.01, 0.1, 1ppm
C6H6 0-10ppm 0-1ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm 0.001, 0.01, 0.1, 1ppm
C7H8 0-10ppm 0-1ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm 0.001, 0.01, 0.1, 1ppm
C8H10 0-10ppm 0-1ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm 0.001, 0.01, 0.1, 1ppm

Filter-to filter the dust and vapour

Drying cylinder-Lower down the humidity and applicated in the high humidity temperature

High Temperature probe SA-Lower down the temperature in 100 ℃

High Temperature probe SB- 2 TYPES for option. Can lower down the temperature in 600 ℃ or 1200℃