Home About Us Careers Clients Contact us Request a quote
HomeAir Monitoring InstrumentsPortable Gas Detectors
Air Monitoring — Family 02

Portable Gas
Detectors.

Handheld instruments for confined-space entry, permit-to-work checks and leak surveys. Single gas where the hazard is known, multi-gas where it is not.

Arka portable gas detectors
ModelsAI-4AS · AI-B00 · AI-C00
TypesSingle · multi · pumped
DutyEntry & survey
OriginDesigned & built in India
The range

Personal, pumped
and multi-gas.

Single-gas personal monitors, multi-gas entry instruments, and pumped detectors for sampling a space before anyone goes in.

AI-4AS Multi-Gas Detector

AI-4AS Multi-Gas Detector

Four-gas instrument with a sampling pump, for drawing an atmosphere out of a vessel or pit before entry.

4 gasPumpedEntry
Enquire
AI-B00 Series Single-Gas Portable Detector

AI-B00 Series Single-Gas Portable Detector

A compact, wearable monitor for one hazard, by natural diffusion. Sound, light, vibration and light-bar alarms, louder than 75 dB at a metre and visible beyond 20 m in the dark, with 12 hours and more on a charge.

Single gasDiffusion≥ 12 hPersonal
Enquire
AI-C00 Series Pump-Suction Portable Detector

AI-C00 Series Pump-Suction Portable Detector

A built-in sampling pump draws gas from tanks, pits, manholes and tunnels before anyone enters. Single gas or the EX / CO / H₂S / O₂ set, IP65, about 300 g, more than 10 hours per charge, with data logging.

PumpedSingle or multiIP65> 10 h
Enquire
Specifications

AI-B00 and AI-C00
side by side.

Portable detectors — specifications
AI-B00 SeriesAI-C00 Series
SamplingNatural diffusionBuilt-in suction pump
Gas optionsO₂, CO, H₂S, NH₃, Cl₂, HCl, CH₄ (catalytic or NDIR), CO₂, VOCs, othersMulti (EX / CO / H₂S / O₂), O₂, H₂S, CO, NH₃, Cl₂, HCl, CH₄ (catalytic or NDIR), CO₂, VOC
AlarmsSound, light, vibration, light barAudible, visual, vibration
Alarm sound> 75 dB at 1 m—
Alarm lightVisible > 20 m in darkness—
Operating time≥ 12 hours> 10 hours
Protection—IP65
Working temperature—−10 to 40 °C
Charging—5 – 7 hours
Size and weight—192 × 66 × 35 mm, about 300 g
Diffusion or pumped?

The one decision
people get wrong.

Diffusion, worn on the person

Gas reaches the sensor by moving with the air. Right for exposure monitoring while somebody works in the area.

Pumped, sampling remotely

A pump draws the atmosphere down a probe. Right for testing a vessel, pit or manhole before entry.

Bump test before each shift

A working instrument is one that alarmed on test gas today, not one that powered on.

Calibrate on a cycle

Sensors drift. Scheduled calibration is what makes the reading defensible after an incident.

Alarm levels set for your site

We configure the thresholds to your permit-to-work limits rather than a factory default.

Sensors replaceable

Electrochemical cells are consumable. We stock the replacements in India.

Kitting out a permit system?

Tell us how many entries a week and which gases. We will specify the instruments and a bump-test regime that survives an audit.